    Brand Name : Topband
    Model Number : TB1240F-S110A_00
    Certification : MSDS, ISO9001, ISO14001
    Supply Ability : 450Mwh/year
    Delivery Time : 2~4weeks for samples; 4~6weeks for mass production
    Price : Negotiable
    Payment Terms : L/C, T/T
    • Product Details
    • Company Profile

    Long Lasting Medical Equipment Batteries 12V 40Ah Prismatic Type

    Long Lasting Medical Equipment Batteries 12V 40Ah Prismatic Lithium Iron Phosphate


    • long life cycle( 2000cycles @ 100%DOD)
    • super quick charge/discharge performance
    • safe pressure valve design ( no explosion, no fire)
    • high energy density
    • low self-discharge( <3% per month)
    • 1/3 weight & 1/2 volume of lead acid battery
    • eco-friendly
    • high consistency
    • no memory effect
    • easily replace lead acid battery

    1. General Information

    This specification defines the performance of rechargeable LiFePO4 battery pack TB1240F-S110A_00

    manufactured by Shenzhen Topband Battery Co., Ltd, describes the type, performance, technical characteristics, warning and caution of the battery pack.


    2. Specification(@Battery initial Temp25±5℃)

    NO.ItemsCriteriaRemarks
    2.1Rated Capacity40Ah
    Minimum Capacity38Ah
    2.2Energy0.512KWh
    2.3Nominal Voltage12.8V
    2.4Outgoing Voltage≥12.8V
    2.5Internal resistance≤40mΩ
    2.6Limited charge voltage14.6±0.1V
    2.7Floating charge voltage13.8±0.2V
    2.8Standard charge current20A
    2.9Maximum charge current40A
    2.10Standard discharge current20A
    2.11Maximum discharge current50A
    2.12Peak discharge current170A/Continuous for 3 s
    2.13Discharge cut-off voltage8.0V(2.0V For each cell)

    2.14

    DimensionLength: 196±2mm
    Width: 165.5±2mm
    Height: 170±2mm
    2.15Weight6.5±0.5kg

    2.16

    Operating TemperatureCharging:0~45℃
    Discharging:-20~60℃
    Recommended operating temperature:15℃~35℃
    2.17Self-discharge rateResidual capacity:≤3%/month;≤15%/years
    Reversible capacity:≤1.5%/month;≤8%/years
    2.18Storage Temperature & Humidity RangeLess than 1 month:-20℃~35℃,45%RH~75%RH
    Less than 3 months:-10℃~35℃,45%RH~75%RH

    Recommended storage environment:

    15℃~35℃,45%RH~75%RH

    Long time storage:

    If the battery need be stored for a long time, the voltage should be 13.2V(50%SOC), and stored in the condition as storage proposal. It need at least one charge & discharge cycle every six months

    3. Test Conditions

    3.1 Standard Test Conditions

    3.1.1 Unless otherwise specified, all performance tests is required conducted at temperature 25℃±2℃, Humidity less than 45%~75%RH.

    3.1.3 Unless otherwise specified, the tested product is required unused within two month after outgoing.

    3.2 Standard Charge Mode

    "Standard Charge" means at 25±2℃ charge to limit voltage with 0.33C constant current, then charge with constant voltage until current less than 0.02ItA.

    3.3 Quick Charge Mode

    " Quick Charge" means at 25±2℃ charge to limit voltage with 0.5 C constant current, then charge with constant voltage until current less than 0.02ItA.

    3.4 Standard Discharge Mode

    "Standard Discharge" means at 25±2℃ discharge to the cut-off voltage with 0.33C current.

    3.5 Quick Discharge Mode

    "Quick Discharge" means discharge to the cut-off voltage with 0.5C current.


    4. Product Performance

    NO.ItemsCriteriaTesting method
    4.1Rated Capacity40AhRest for 1 hour after fully charged, then discharge with 0.33C current until the battery reaches the discharge cutoff voltage. Repeat above process for three times, if the discharge time is not less than 120 minutes, you can stop and define the Discharging current*time value (Ah) as battery capacity.
    4.2Minimum Capacity38Ah
    4.3Internal resistance≤40mΩ50% battery SOC state frequency of 1 KHZ ac resistance tester
    4.5

    Cycle life

    (DOD100%)

    ≥2000cycleDischarge with the current of 0.33C until it can’t discharge, and then rest it for 1h. Charge the battery following CC(0.33C)/CV(14.6V) mode to full capacity, and then rest it for 1h. Repeat above process until full charged capacity is no more than 80% of normal value. Accumulated times is defined as cycle life.
    4.6

    Discharge Temperature

    Characteristics

    -20℃≥70%At 25±5℃ discharge the battery with the current of 0.33C to the cut-off voltage and record charge capacity. Store the battery at various temperatures for 2h and discharge the battery with 0.33C to the cut-off voltage.
    -0℃≥80%
    25℃≥100%
    55℃≥95%
    4.7Charge Retention ability

    Residual

    capacity≥80%

    Charge the battery to full capacity and store it for 28days, and then discharge it with 0.33C to the cut-off voltage.
    Recovery capacity≥90%

    5. Protective circuit specification

    The batteries are supplied with a LiFePO4 Battery Management System (BMS)that can monitor and optimized each single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge, short circuit. Overall, the BMS helps to ensure safe and accurate running.


    NO.ItemsContentSpecification
    5.1Over chargeOver-charge protection for each cell3.80±0.03V
    Over-charge release for each cell3.60±0.05V
    Over-charge release methodUnder the release voltage
    5.2Over dischargeOver-discharge protection for each cell2.0±0.08V
    Over-discharge release for each cell2.3±0.1V
    Over-discharge release methodCharging recovery
    5.3Over currentDischarge over current protection195A±25A
    Protection delay time0.5±1.5s
    Over current release methodRelease after cutoff the load.
    5.4ShortNO.Ban electrode short circuit
    5.5Battery temperatureCharge over temperatureProtection @65±5℃
    Release @50±10℃
    Discharge over temperatureProtection @65±5℃
    Release @50±10℃

    Charge over temperature

    protection MOS

    Protection @100±5℃
    Release @70±15℃

    Discharge over temperature

    Protection MOS

    Protection @100±5℃
    Release @70±15℃
    5.6Static powerSince the power consumption≤3mA;After discharge protection≤150uA